Su/Sg (K-Sequence) - Fuji Electric Monitouch V9 Series Connection Manual

Hide thumbs Also See for Monitouch V9 Series:
Table of Contents

Advertisement

7-10
7. KOYO ELECTRONICS
7.1.3

SU/SG (K-Sequence)

Communication Setting
Editor
Communication setting
Connection Mode
Signal Level
Baud Rate
Data Length
Stop Bit
Parity
Target Port No.
SU-5M/6M
Programmer Communication Port
No particular setting is necessary on the PLC. The PLC always performs communication functions using the following
parameters. Set the following parameters under [Communication Setting] of the editor.
Baud Rate
Parity
Data Length
Stop Bit
Data Type
Universal Communication Port 1
Set parameters into the special register "R772, 773", then set "AA5A" (HEX) into the setting complete register "R767". When
the set value at R767 is changed to "AAAA" (HEX), it is regarded as normal; if it is changed to "AAEA" (HEX), it is regarded as
erroneous.
Item
4800 / 9600 / 19200 / 38400 bps
Item
Setting
1 : 1 / Multi-link2 /
Multi-link2 (Ethernet)
RS-232C / RS-422/485
8 bits
1 / 2 bits
None / Odd / Even
0 to 31
Setting
9600 bps
Odd
8
1
HEX
(Underlined setting: default)
Remarks