Counter reset
Shutter
Print trigger
One-point laser irradiation
Step & repeat
Reading of
condition
condition
15.2 Temperature Controller/Servo/Inverter Connection
F0
n
n + 1
n + 2
n + 3
n + 4
1 - 8
n + 5
(PLC1 - 8)
n + 6
n + 7
n + 8
n + 9
n
n + 1
1 - 8
(PLC1 - 8)
n + 2
n
n + 1
1 - 8
(PLC1 - 8)
n + 2
n
n + 1
1 - 8
(PLC1 - 8)
n + 2
n
n + 1
n + 2
n + 3
n + 4
n + 5 to n + 6
1 - 8
(PLC1 - 8)
n + 7 to n + 8
n + 9
F1 (= $u n)
Station number: 0 (fixed)
Command: A6H
Counter 0
0: Not reset
1: Reset
Counter 1
0: Not reset
1: Reset
Counter 2
0: Not reset
1: Reset
Counter 3
0: Not reset
1: Reset
Counter 4
0: Not reset
1: Reset
Counter 5
0: Not reset
1: Reset
Counter 6
0: Not reset
1: Reset
Counter 7
0: Not reset
1: Reset
Station number: 0 (fixed)
Command: A7H
Shutter status
0: Shutter close
1: Shutter open
Station number: 0 (fixed)
Command: A8H
Print command
0: Stop
1: Start
Station number: 0 (fixed)
Command: A9H
0: Stop
1: Start
2: Suspend
Station number: 0 (fixed)
Command: 2AH
Step & repeat
0: None
1: Provided
Number of lines: 001 to 100
Number of columns: 001 to 100
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
0 to 110000:
Line step
000.000 to 110.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
0 to 55000:
000.000 to 055.000 mm
Column
LP-435U/435TU/425S9U/425S9TU
step
000 to 160000:
000.000 to 160.000 mm
Counter motion
0000H: Same for all steps
001xH: Unallocated number
002xH: Serial number
00x0H: From top left toward right
00x1H: From top left toward bottom
00x2H: From top right toward left
00x3H: From top right toward bottom
15-43