Fuji Electric Monitouch V9 Series Connection Manual page 26

Hide thumbs Also See for Monitouch V9 Series:
Table of Contents

Advertisement

PLC properties
Configure [Communication Setting] on the [PLC Properties] window.
Item
Connection Mode
Signal Level
Baud Rate
Data Length
Stop Bit
Parity
Target Port No.
Transmission Mode
For settings other than the above, see "1.4 Hardware Settings" (page 1-43).
Settings of a Connected Device
Refer to the chapter of the respective manufacturer.
For descriptions of connecting PLCs, refer to the manual for each PLC.
Wiring
DANGER
CN1
The wiring between a V9 and a connected device is the same as that for 1 : 1 communication. For description of wiring
between connected devices, refer to the manuals issued by the manufacturers.
RS-422 (4-wire system) connection
 Connection example
CN1
Dsub 9 (Male)
6
9
Terminating resistance ON
1 : n
RS-422/485
Configure according to the connected device.
Be sure to turn off the power before connecting cables. Otherwise, electrical shock or damage may
occur.
No.
Name
FG
+RD
1
1
-RD
2
5
-SD
3
+SD
4
SG
5
Contents
RS-422 port of the
connected device
FG
Send data (+)
Send data ()
Receive data ()
Receive data (+)
SG
For wiring between connected devices, refer
to the manuals issued by the manufacturers.
1.3 Connection Methods
RS-422 port of the
connected device
FG
Send data (+)
Send data ()
Receive data ()
Receive data (+)
SG
1-15