5.1.7

KV-1000 (Ethernet TCP/IP)

Communication Setting
Editor
Make the following settings on the editor. For more information, see "1.3.2 Ethernet Communication".
 IP address for the V9 unit
- When specified on the screen program:
[System Setting]  [Hardware Setting]  [Local Port IP Address]
- When specified on the V9 unit:
Local mode  [LAN Setting]
 Port number for the V9 unit (for communication with PLC)
[System Setting]  [Hardware Setting]  [PLC Properties]  [Communication Setting]
 IP address and port number of the PLC
Register on the [PLC Table] in [System Setting]  [Hardware Setting]  [PLC Properties]  [Target Settings].
PLC
The communication setting is the same as the one described in "5.1.5 KV-700 (Ethernet TCP/IP)".
Available Device Memory
The available setting range of device memory varies depending on the PLC model. Be sure to set within the range available for
the PLC to be used. Use [TYPE] when assigning indirect device memory for macro programs.
DM
(data memory)
R
(input/output/internal auxiliary/special relay)
TC
(timer/current value)
CC
(counter/current value)
TS
(timer/set value)
CS
(counter/set value)
T
(timer/contact)
C
(counter/contact)
TM
(temporary data memory)
CTH
(high-speed counter/current value)
CTC
(high-speed counter comparator/set value)
CT
(high-speed counter comparator/contact)
CR
(control relay)
CM
(control memory)
MR
(internal auxiliary relay)
LR
(latch relay)
EM
(extended data memory 1)
FM
(extended data memory 2)
Z
(index register)
Device Memory
5.1 PLC Connection
TYPE
00H
01H
02H
03H
04H
05H
06H
07H
08H
09H
0AH
0BH
0CH
0DH
0EH
0FH
10H
11H
12H
5-11