14-4
14. Oriental Motor

14.1.2 CRK Series (MODBUS RTU)

Communication Setting
Editor
Communication setting
Item
Connection Mode
Signal Level
Baud Rate
Data Length
Stop Bit
Parity
Target Port No.
Stepping Motor
MEXE02 (application software)
Setting changes will take effect after turning the power off and back on. If changes are made to any settings, turn the power
off and on again.
Item
Communication device number
Communication protocol
Parity
Stop bit
Communication timeout
Device number setting switch (SW1)
SW1
4
Function setting switches (SW2)
SW2
Terminating resistance setting switch (SW3)
SW3
OFF
ON
Setting
1 : 1 / 1 : n / Multi-link2 /
Multi-link2 (Ethernet) /
1 : n Multi-link2 (Ethernet)
RS-422/485
9600 / 19200 / 38400 / 57600 / 115K bps
8 bits
1 / 2 bits
None / Odd / Even
0 to 31
Setting
1 to 31
Modbus RTU
None / Even / Odd
1 / 2 bits
0 to 10000 ms
Setting Item
Device number
No.
Setting Item
1
2
Baud rate
3
4
Connected device
Setting Item
Terminating resistance
0: Broadcast
Remarks
This setting is valid, provided that the device number setting switch
(SW1) is set to "F".
* Do not use device No. 0.
0: No check
* If the V series performs no communication for a set timeout
period (other than "0"), an alarm occurs at the stepping motor.
Setting
1 to E: 1 to 14
F: Device number of the communication
device number parameter in MEXE02
Setting
No. 1
No. 2
9600 bps
OFF
OFF
19200 bps
ON
OFF
38400 bps
OFF
ON
57600 bps
ON
ON
115200 bps
OFF
OFF
ON: Universal master device
Setting
ON: With terminating resistance
OFF: Without terminating resistance
(Underlined setting: default)
Remarks
(Underlined setting: default)
Remarks
Do not use device No. 0.
Remarks
No. 3
OFF
OFF
OFF
OFF
ON
Remarks