SG-8
Universal Communication Port
System parameter setting
Set the station number using the system parameter setting of the programmer. For more information, refer to the PLC manual
issued by the manufacturer.
Station number
Data type
The following settings are fixed; data length: 8 bits, parity: odd, and stop bit: 1 bit.
DIP switch
The DIP switch provided at the rear of the CPU is used to make the following settings.
Switch
Host Link Module (G-01DM)
Online/offline selector switch
Selector Switch
ONLINE
OFFLINE
DIP switch (SW1)
SW1
ON
Item
Item
No. 1
Signal level
Station number
No. 2
setting
No. 3
Baud rate
No. 4
Online
Item
No. 1
No. 2
No. 3
Station number
No. 4
setting
No. 5
No. 6
No. 7
No. 8
P-P setting
Master/slave
No. 9
setting
Setting
1 to 90
HEX
Setting
OFF: RS-422
ON:
RS-232C
OFF: According to the system parameter setting
ON:
Fixed to 01
SW3
9600 bps
ON
19200 bps
ON
Setting
Setting
1 to 90
1
2
3
4
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
:
:
:
:
:
88
OFF
OFF
OFF
ON
89
ON
OFF
OFF
ON
90
OFF
ON
OFF
ON
OFF
OFF: Slave
7.1 PLC Connection
(Underlined setting: default)
Remarks
Valid only when DIP switch No. 2 is set to OFF
(Underlined setting: default)
SW4
OFF
ON
(Underlined setting: default)
5
6
7
For more information on any
OFF
OFF
OFF
station number settings
OFF
OFF
OFF
other than those given on
OFF
OFF
OFF
the left, refer to the PLC
:
:
:
manual issued by the
ON
OFF
ON
manufacturer.
ON
OFF
ON
ON
OFF
ON
7-7
Remarks
Remarks