Fuji Electric Monitouch V9 Series Connection Manual page 455

Hide thumbs Also See for Monitouch V9 Series:
Table of Contents

Advertisement

17-4
17. RS Automation
NX70-CPU70p1 (COM Port)
DIP switches
DIPSW
ON
NX70-CPU70p2 (COM Port) / NX-CPU700p (COM Port)
DIP switches 1
DIPSW1
ON
DIP switches 2
DIPSW2
ON
Contents
SW1
Terminating resistance
(for RS-485 connection)
SW2
SW3
Program write target
SW4
RS-232C / RS-485 selection
SW5
Baud rate selection
SW6
Contents
SW1
COM1 terminating resistance
(for RS-485 connection)
SW2
SW3
COM2 terminating resistance
(for RS-485 connection)
SW4
Contents
SW1
Program write target
SW2
Not used
SW3
RS-232C / RS-485 selection (COM2)
SW4
RS-232C / RS-485 selection (COM1)
SW5
Baud rate selection (COM1)
SW6
SW7
Baud rate selection (COM2)
SW8
Setting
Terminating
SW1
SW2
Resistance
OFF
OFF
Invalid
ON
ON
Valid
ON: EEPROM
OFF: RAM
ON: RS-485
OFF: RS-232C
SW5
SW6
Baud rate
OFF
OFF
9600bps
ON
OFF
38400bps
OFF
ON
19200bps
ON
ON
4800bps
Setting
Terminating
SW1
SW2
Resistance
OFF
OFF
Invalid
ON
ON
Valid
Terminating
SW3
SW4
Resistance
OFF
OFF
Invalid
ON
ON
Valid
Setting
ON: EEPROM
OFF: RAM
OFF
ON: RS-485
OFF: RS-232C
ON: RS-485
OFF: RS-232C
SW5
SW6
Baud Rate
OFF
OFF
9600bps
ON
OFF
38400bps
OFF
ON
19200bps
ON
ON
4800bps
SW7
SW8
Baud Rate
OFF
OFF
9600bps
ON
OFF
38400bps
OFF
ON
19200bps
ON
ON
4800bps