15.2.1 LP-400 Series

Communication Setting
Editor
Communication setting
Item
Connection Mode
Signal Level
Baud Rate
Data Length
Stop Bit
Parity
Sum Check
CR/LF
Laser Marker
Parameter
Set communication parameters using the console. For more information, refer to the instruction manual for the laser marker
issued by the manufacturer.
Mode
Environment
Communication I/O
setting
DIP switch
DPS-8
1
2
3
4
5
6
DPS-8
* Keep the power off when changing the DIP switch setting.
* For communications with the V series, be sure to switch to the remote mode.
1 : 1 / Multi-link2 / Multi-link2 (Ethernet)
4800 / 9600 / 19200 / 38400 bps
None / Odd / Even
Provided / Not provided
Sub Menu
Baud Rate
Data Length
Parity
Stop Bits
Delimit
Check Sum
SW
Contents
No.
1
System reserve
2
External control method
Buzzer at an occurrence
3
of error
4
Password lock
5
7
8
Method to switch to
remote mode
6
7
System reserve
8
System reserve
15.2 Temperature Controller/Servo/Inverter Connection
Setting
RS-232C
8 bits
1 / 2 bits
CR / CR/LF
Item
4800 / 9600 / 19200 / 38400 bps
8 bit
None / Odd / Even
1 / 2 bit
CR / CR+LF
None / Provided
OFF:
System reserved
ON:
RS-232C control
ON:
Not sound
OFF:
Sound
ON:
Password lock invalid
OFF:
Password lock valid
SW5
SW6
OFF
OFF
ON
OFF
OFF
ON
OFF:
System reserved
OFF:
System reserved
(Underlined setting: default)
Remarks
(Underlined setting: default)
Setting
Setting
Operation
Pressing the remote button on
the front of the controller
Inputting "REMOTE IN" on the
terminal block
Turning the key switch ON
15-27
Remarks
Remarks