PLC_CTL
Macro command "PLC_CTL F0 F1 F2"
Contents
Controller status read out
Operation instructions
*1
8000 (HEX): broadcasting
*2
Valid only for the product of pulse output type or analog output type
13.2 Temperature Controller/Servo/Inverter Connection
F0
n
Station number
n + 1
Command: 06H
Operation status (higher byte)
00: Control in execution for all channels
(Operation in progress while the setting area is "0" with no
error occurring.)
1 - 8
01: Control stopping at any of the channels
(PLC1 - 8)
(Other than above)
n + 2
Related information (lower byte)
n
Station number
n + 1
Command: 0030H
Communication writing
0000H: Communication writing OFF (disabled)
0001H: Communication writing ON (enabled)
Control start/stop
0100H: Channel 1 run
0101H: Channel 1 stop
0110H: Channel 2 run
0111H: Channel 2 stop
01F0H: All-channel run
01F1H: All-channel stop
Multi-SP
0200H: Channel 1 target value 0
0201H: Channel 1 target value 1
0210H: Channel 2 target value 0
0211H: Channel 2 target value 1
02F0H: All-channel target value 0
02F1H: All-channel target value 1
AT execution
0300H: Channel 1 AT execute
0301H: Channel 1 AT cancel
0310H: Channel 2 AT execute
0311H: Channel 2 AT cancel
03F0H: All-channel AT execute
1 - 8
03F1H: All-channel AT cancel
(PLC1 - 8)
Write mode
n + 2
0400H: Backup mode
0401H: RAM write mode
0500H: Save RAM data
0600H: Software reset
0700H: Move to set area 1
0800H: Move to protection level
Auto/manual
0900H: PV hold
0B00H: Initialize
Unlatch
0C00H: Channel 1 warning 1 unlatch
0C01H: Channel 1 warning 2 unlatch
0C031H: Channel 1 warning 3 unlatch
0C0FH: Channel 1 all warnings unlatch
0C10H: Channel 2 warning 1 unlatch
0C11H: Channel 2 warning 2 unlatch
0C13H: Channel 2 warning 3 unlatch
0C1FH: Channel 2 all warnings unlatch
0CF0H: All channels warning 1 unlatch
0CF1H: All channels warning 2 unlatch
0CF2H: All channels warning 3 unlatch
0CFFH: All channels all warnings unlatch
F1 (= $u n)
Bit
-
7 6 5 4 3 2 1 0
Blank
Blank
Input error
*1
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
Return data: Data stored from temperature controller to V series
13-49
Overcurrent
Current hold
*2
F2