3.4 Controlling the Pre-Transfer Charging

3.4.1 Outline

The system used for pre-transfer charging serves the following functions:
1. Controlling the DC bias to a specific level of current.
2. Controlling the AC bias to a specific level of voltage.
3. Controlling the output to suit the environment (fuzzy control).
The system used to control the pre-transfer charging is constructed as follows:
J510A
1
2
3
4
5
PT/SP-LEAK-DETECT [1]
6
7
8
9
10
11
12
PT/SP-CNT [2]
13
14
PT/SP-REMOTE [3]
15
16
The following signals are used:
[1] pre-transfer/separation charging leakage detection signal: '0' when an excessively high
or low level of current is detected.
[2] pre-transfer charging control signal; the output of pre-transfer current turns ON when
the voltage is about 3 V or more and less than 11 V; it turns OFF when the voltage is
about 12 V or more.
[3] pre-transfer/separating charging remote signal; turns on/off the output of the pre-trans-
fer/separation current.
COPYRIGHT © 2000 CANON INC.
Download Free Service Manual at http://printer1.blogspot.com
J4502
16
15
14
13
12
11
10
9
8
7
6
5
J4505
4
3
3
2
2
1
1
F04-304-01
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 4 IMAGE FORMATION SYSTEM
The level of current of the
pre-transfer bias varies as follows
in keeping with the potential of
PT-SP-CNT.
-300µA
3V
PT/SP-CNT
Pre-transfer charging wire
T4501
11V12V
AC+DC
4-23 P