Show Virtual-Chassis Status - Juniper JUNOS OS 10.3 - SOFTWARE Manual

For ex series ethernet switches
Hide thumbs Also See for JUNOS OS 10.3 - SOFTWARE:
Table of Contents

Advertisement

Complete Software Guide for Junos
Results
Verification
Purpose
Action
968
®
OS for EX Series Ethernet Switches, Release 10.3
NOTE: We recommend that you use the
to save any configuration changes that you make to a multimember
Virtual Chassis.
Display the results of the configuration on SWA-0:
[edit]
user@SWA-0# show virtual-chassis
member 0 {
mastership-priority 255;
}
member 1 {
mastership-priority 128;
}
member 2 {
mastership-priority 255;
}
member 3 {
mastership-priority 128;
}
}
To confirm that the configuration is working properly, perform these tasks:
Verifying the Member IDs and Roles of the Member Switches on page 968
Verifying that the Dedicated VCPs and Uplink VCPs Are Operational on page 969
Verifying the Member IDs and Roles of the Member Switches
Verify that all the interconnected member switches are included within the Virtual Chassis
configuration and that their roles are assigned appropriately.
Display the members of the Virtual Chassis configuration:
user@SWA-0> show virtual-chassis status
Virtual Chassis ID: 0000.e255.00e0
Member ID
Status
Serial No
0 (FPC 0)
Prsnt
abc123
1 (FPC 1)
Prsnt
def456
2 (FPC 2)
Prsnt
ghi789
commit synchronize
Mastership
Model
Priority
Role
ex4200-48p
255
Master*
ex4200-24t
128
Linecard
ex4200-48p
255
Backup
Copyright © 2010, Juniper Networks, Inc.
command
Neighbor List
ID Interface
1 vcp-0
2 vcp-1
2 vcp-255/1/0
0 vcp-0
0 vcp-1
3 vcp–255/1/0
3 vcp-0

Advertisement