Download Print this page

Danfoss iC7 Series Application Manual page 98

Hide thumbs Also See for iC7 Series:

Advertisement

Application Guide | iC7 Series Industry
Data Type:
UINT
The following are the selections for the parameter.
Selection Number
Selection Name
1
Fault
2
Automatically derate
This parameter selects a response to the reaction of the drive for rectifier thermal overload protection. Rectifier thermal overload is
detected when the drive operates for a long period at a specified rectifier current level. Specific current levels and trip times depend on
the power unit type and rating. Following are the descriptions for the selections available for the parameter:
Table 29: Selection Descriptions
Selection Name
Trip
Automatically derate
P 2.3.1.6 Inverter Thermal Overload Response
Select the mode of inverter thermal overload protection.
Default Value:
1 (Fault)
Parameter
2341
Number:
Data Type:
UINT
The following are the selections for the parameter.
Selection Number
Selection Name
1
Fault
2
Automatically derate
This parameter selects a response to the reaction of the drive for Inverter Thermal Overload protection. Inverter thermal overload is
detected when the drive operates for a long period at a specified output current level. Specific current levels and trip times depend on
the power unit type and rating. Following are the descriptions for the selections available for the parameter:
Table 30: Selection Descriptions
Selection Name
Trip
Automatically derate
98
| © 2024.05
Selection Description
The drive issues a fault and stops modulation.
The drive derates the rectifier current (DC-link current) to mitigate the cause of rectifier thermal
overload. When the drive exits from the overload operation window, derating is stopped.
Selection Description
The drive issues a fault and stops modulation.
The drive derates the rectifier current (DC-link current) to mitigate the cause of rectifier thermal
overload. When the drive exits from the overload operation window, derating is stopped.
Access Type:
Selection Description
The drive issues a fault and stops.
The drive continues operation with derated performance.
Parameter Type:
Unit:
Access Type:
Selection Description
The drive issues a fault and stops.
The drive continues operation with derated performance.
Parameter Descriptions
Read/Write
Selection
Read/Write
AB480436531518en-000601 / 136R0283

Advertisement

loading
Need help?

Need help?

Do you have a question about the iC7 Series and is the answer not in the manual?