Application Guide | iC7 Series Industry
P 5.5.6.1.11 Advanced Reset Input
Select inputs for resetting faults when operating in advanced control.
Default Value:
Parameter
4731
Number:
Data Type:
UINT
P 5.5.6.1.13 Advanced Start Mode
Select the starting logic for advanced control.
Default Value:
0 (State High Start)
Parameter
4726
Number:
Data Type:
UINT
The following are the selections for the parameter.
Selection Number
Selection Name
0
State High Start
1
Rising Edge Start
2
High Pulse Start
P 5.5.6.1.15 Fieldbus CTW Feature Bits
Enables non-control-place-dependent control word bits to be active in advanced control place.
Default Value:
1 (Enabled)
Parameter
4627
Number:
Data Type:
BOOL
The following are the selections for the parameter.
Selection Number
Selection Name
0
Disabled
1
Enabled
References (Menu Index 5.5.6.2)
6.6.6.7.2
P 5.5.6.2.1 Adv. Speed Reference Source
176
| © 2024.05
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Selection Description
Start command remains as long as input is true.
Start command is set when input becomes true and remains
latched until stop command is given.
Start command is set when input becomes true and remains
latched until stop command is given.
Parameter Type:
Unit:
Access Type:
Selection Description
Disables the function.
Enables the function.
Parameter Descriptions
Selection
Read/Write
Selection
Read/Write
Selection
Read/Write
AB480436531518en-000601 / 136R0283