Application Guide | iC7 Series Industry
Table 50: Status Word Description
Bit
Bit Name
Number
0
Enabled
1
Start
2
Brake open feedback signal
3
Brake close feedback
4–10
N/A
11
Priming
12
Brake release timeout
13
Brake close timeout
14
BrakeCtrl active
15
Brake open
P 5.12.1.2 Mechanical Brake State
Shows the state of the mechanical brake controller.
Default Value:
NA
Parameter
3017
Number:
Data Type:
INT
P 5.12.1.3 Brake Release Time Detected
Shows the time from brake release until load change is detected, where motor takes over the load from mechanical brake.
Default Value:
NA
Parameter
3041
Number:
Data Type:
REAL
6.7.2.13
Maintenance & Service (Menu Index 6.1.1)
P 6.1.1.1 Last Fault Number
Shows the number of the most recent active fault.
Default Value:
NA
Parameter
1610
Number:
Data Type:
UINT
284
| © 2024.05
Description
Mechanical brake is enabled by a parameter.
A start signal is provided to mechanical brake control.
Brake feedback is enabled and brake open is active.
Brake feedback is enabled and brake closed is active.
The required release torque could not be generated.
Feedback is enabled but brake open feedback was not provided during brake
release time.
Feedback is enabled but brake close feedback was not provided during brake
close time.
Brake control is either in progress of opening or closing brake.
Brake control has activated digital output.
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Descriptions
Range (0 — 32767)
–
Read Only
Range (0 — 10000)
s
Read Only
Range (0 — 65535)
–
Read Only
AB480436531518en-000601 / 136R0283
Need help?
Do you have a question about the iC7 Series and is the answer not in the manual?