Application Guide | iC7 Series Industry
Index
5.4.2.16
4.
Configure the type of torque reference used for the Advanced Control Place.
Index
5.5.6.2.4
5.5.6.2.5
5.
Configure the torque limit settings.
Index
5.9.2.1
5.9.2.2
5.9.2.3
5.9.2.4
5.9.2.5
See more information about flexible limit modes in 6.6.9.3 Limits (Menu Index 5.9.2).
5.9.2.4 Regenerative Torque Limit
-5.9.2.3 Motoring Torque Limit
Figure 53: Torque Control Limits
6.
Configure the reference settings and terminals used for the reference signal.
© 2024.05
Parameter name
Operation Mode
Parameter name
Adv. Torque Reference
Adv. Torque Reference Logic
Parameter name
Positive Torque Limit
Negative Torque Limit
Motoring Torque Limit
Regenerative Torque Limit
Speed Limit Mode Torque Ctrl.
Torque
Motoring
Quadrant 2
Motoring
Quadrant 3
Example setting
Torque control
Example setting
Fieldbus reference, Reference 1 input
Sum
Example setting
150%
-150%
100%
100%
Pos./Neg. speed limit
Motoring
Quadrant 1
5.9.2.1 Positive Torque Limit
5.9.2.3 Motoring Torque Limit
Speed
-5.9.2.4 Regenerative Torque Limit
5.9.2.2 Negative Torque Limit
Motoring
Quadrant 4
Configuration Set-up Examples
Parameter
number
2500
Parameter
number
1929
1919
Parameter
number
1810
1811
1321
1323
2332
AB480436531518en-000601 / 136R0283 |