Application Guide | iC7 Series Industry
Data Type:
UINT
The following are the selections for the parameter.
Selection Number
Selection Name
1
Local control
2
Fieldbus control
3
I/O control
4
Advanced control
P 5.5.2.10 Alternative Control Place Input
Select the digital input terminal for activating the alternative control place.
Default Value:
Parameter
111
Number:
Data Type:
UINT
Local Control (Menu Index 5.5.3)
6.6.6.4
Settings (Menu Index 5.5.3.1)
6.6.6.4.1
P 5.5.3.1.1 Allow Local Control Force Stop
Select whether the control panel stop button always stops the drive, regardless of the selected control place. Pressing the stop button
also places the drive in local control.
Default Value:
1 (Enabled)
Parameter
106
Number:
Data Type:
BOOL
The following are the selections for the parameter.
Selection Number
Selection Name
0
Disabled
1
Enabled
P 5.5.3.1.2 Local Control Mode
Select restrictions of local control by the control panel.
Default Value:
0 (Allow Local Control)
Parameter
107
Number:
© 2024.05
Access Type:
Selection Description
The drive is controlled by a connected control panel.
The drive is controlled via a fieldbus.
The drive is controlled via I/O.
The drive is controlled via a combination of I/O and fieldbus.
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Selection Description
Disables the function.
Enables the function.
Parameter Type:
Unit:
AB480436531518en-000601 / 136R0283 |
Parameter Descriptions
Read/Write
Selection
Read/Write
Selection
Read/Write
Selection
161