Table 8: Drive Status Texts
(continued)
Drive status in the panel
Running at Standstill
Stopping
Stopped
Coasted
Quick Stop
Start Interlock
Start Blocked
Disabled Reference
Reversing
Reversing at Reference
Motor Disconnected
Fault ! Start Blocked
Fault ! Stopping
Fault ! Derating
Safe Torque Off (STO)
Safe Stop (SS1/SS2)
Inching
Inching at Standstill
Inching at Reference
Running Frozen Reference
Stopping Frozen Reference
Running/Stopping/Inching with:
• Power Limit
• Undervoltage Limit
• Overvoltage Limit
• Torque Limit
• Current Limit
• Speed Limit
AMA Ready
AMA in Progress
36
| © 2024.05
Description
The drive is running with 0 reference.
The drive is running towards stop.
The drive is stopped due to an active stop command.
The drive is coasting due to an active coast command.
The drive is stopped due to an active quick stop command.
The drive is stopped with an active start command. To restart, the start command must
be removed and given again.
The drive is in a state that is preventing start. All start commands are ignored.
The drive setpoint has been disabled with the PROFIdrive Control Word (see
trol Word
(CTW)).
The drive is reversing due to an active reverse command.
The drive is reversing at the selected reference.
The drive has detected a disconnected motor (see parameter 4.5.3 Disconnected Motor
Response in
6.5.5 Protection (Menu Index
The drive has an active fault that is preventing start.
The drive has detected a fault and is running towards stop.
The drive is derating its output to thermally protect the Advanced Harmonic Filter (see
parameter 3.4.3 Thermal Switch Response in
3.4)).
The drive is coasting due to an active STO command.
The drive is stopping on a safe stop command.
The drive is inching or jogging.
The drive is inching with 0 reference.
The drive is inching with the selected inching reference.
The drive is running at frozen reference due to an active frozen reference command.
The drive is running towards stop due to an active stop command with a frozen refer-
ence command.
The drive is running, stopping, or inching, and has exceeded the limit that is shown. For
example, Running - Power Limit.
Some possible limits are listed in the cell on the left.
Advanced Motor Adaptation is activated and is waiting for the start command.
Advanced Motor Adaptation is running, measuring motor data.
4.5)).