Application Guide | iC7 Series Industry
Parameter
6006
Number:
Data Type:
REAL
Editing the setpoint falling time ramp defines the ramp-down time. The falling ramp for the setpoint is defined as slew rates which refers
to process unit per time such as bar/s, ºC/s. Setting the parameter to high values (compared to the dynamics of the requested setpoint)
disables the ramp-down function.
P 5.10.3.23 Process Ref. Lowpass Filter Tc
Set the time constant of the reference filter. Setting it to 0 disables the filter.
Default Value:
Parameter Type:
Parameter
6083
Number:
Data Type:
REAL
P 5.10.3.24 Process Controller Start Speed
Set the start speed of the process controller.
Default Value:
Parameter Type:
Parameter
6056
Number:
Data Type:
REAL
P 5.10.3.26 Fieldbus Process Reference Scale
Set the fieldbus reference scale equal to 100% reference.
Default Value:
10
Parameter
6030
Number:
Data Type:
REAL
Feedback (Menu Index 5.10.4)
6.6.11.5
P 5.10.4.1 Feedback Mode
Select the function to combine feedback 1 and feedback 2.
Default Value:
0 (Feedback 1)
Parameter
6008
Number:
Data Type:
UINT
The following are the selections for the parameter.
240
| © 2024.05
Unit:
Access Type:
Range (0.00 — 30000.00)
Unit:
Access Type:
Range (-1000 — 1000)
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Descriptions
–
Read/Write
ms
Read/Write
Hz
Read/Write
Range (-1000000 — 1000000)
CustomProcessUnit
Read/Write
Selection
–
Read/Write
AB480436531518en-000601 / 136R0283