Download Print this page

Danfoss iC7 Series Application Manual page 219

Hide thumbs Also See for iC7 Series:

Advertisement

Application Guide | iC7 Series Industry
Default Value:
590
Parameter
677
Number:
Data Type:
REAL
6.6.9.11
Auto Tuning (Menu Index 5.8.11)
P 5.8.11.1 Speed Controller Auto Tuning
Enables the auto tuning of the speed controller. Auto tuning is started when the value of the parameter "5.3.2.4 System Inertia" is
changed and unequal to "0".
Default Value:
False
Parameter
4546
Number:
Data Type:
BOOL
P 5.8.11.2 Auto Tuning Bandwidth
Set the auto tuning bandwidth. A higher value leads to a faster response to speed or reference changes.
Default Value:
100
Parameter
4547
Number:
Data Type:
REAL
P 5.8.11.3 System Friction
Set the total system friction in % of the nominal motor torque at nominal motor speed.
Default Value:
Parameter Type:
Parameter
4548
Number:
Data Type:
REAL
© 2024.05
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Range (0 — 100)
Unit:
Access Type:
AB480436531518en-000601 / 136R0283 |
Parameter Descriptions
Range (\* — \*)
Hz
Read/Write
Range (False — True)
Read/Conditional Write
Range (0 — 1000)
%
Read/Write
%
Read/Write
219

Advertisement

loading
Need help?

Need help?

Do you have a question about the iC7 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel