Application Guide | iC7 Series Industry
Parameter
6152
Number:
Data Type:
REAL
P 5.9.1.7 Torque Reference Final
Shows the value of the final torque reference given to the motor controller in % of nominal motor torque.
Default Value:
NA
Parameter
6154
Number:
Data Type:
REAL
6.6.10.3
Limits (Menu Index 5.9.2)
P 5.9.2.1 Positive Torque Limit
Set the positive torque limit (quadrants 1 and 2) in % of nominal motor torque.
Default Value:
300
Parameter
1810
Number:
Data Type:
REAL
P 5.9.2.2 Negative Torque Limit
Set the negative torque limit (quadrants 3 and 4) in % of nominal motor torque.
Default Value:
-300
Parameter
1811
Number:
Data Type:
REAL
P 5.9.2.3 Motoring Torque Limit
Set the torque limit in motoring mode (quadrants 1 and 3) in % of nominal motor torque.
Default Value:
300
Parameter
1321
Number:
Data Type:
REAL
P 5.9.2.4 Regenerative Torque Limit
Set the torque limit in regenerative mode (quadrants 2 and 4) in % of nominal motor torque.
Default Value:
300
Parameter
1323
Number:
224
| © 2024.05
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Parameter Descriptions
%
Read/Write
Range (-300 — 300)
%
Read Only
Range (0 — 500)
%
Read/Write
Range (-500 — 0)
%
Read/Write
Range (0 — 500)
%
Read/Write
Range (0 — 500)
%
AB480436531518en-000601 / 136R0283