Application Guide | iC7 Series Industry
Default Value:
Parameter Type:
Parameter
1135
Number:
Data Type:
REAL
P 5.8.6.6.4 Decel. Time Input
Select the input or a fixed value for adjusting the variable ramp deceleration time.
Default Value:
–
Parameter
1133
Number:
Data Type:
UINT
P 5.8.6.6.5 Decel. Time Maximum
Set the maximum of the deceleration time for the variable ramp.
Default Value:
120
Parameter
1136
Number:
Data Type:
REAL
P 5.8.6.6.6 Decel. Time Minimum
Set the minimum of the deceleration time for the variable ramp.
Default Value:
Parameter Type:
Parameter
1137
Number:
Data Type:
REAL
Speed Feedback (Menu Index 5.8.7)
6.6.9.8
P 5.8.7.1 Speed Feedback Filter Tc
Set the speed feedback filter time constant (when the speed is controlled with speed sensor).
Default Value:
5.00
Parameter
4544
Number:
Data Type:
REAL
P 5.8.7.2 Estimated Speed Filter Tc
Set the filter time constant for the estimated speed (when the speed is controlled without speed sensor).
Default Value:
10.00
214
| © 2024.05
Range (0 — 10000)
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Range (0 — 10000)
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Parameter Descriptions
s
Read/Write
Selection
–
Read/Write
Range (0 — 10000)
s
Read/Write
s
Read/Write
Range (0.00 — 1000.00)
ms
Read/Write
Range (5.00 — 100000.00)
AB480436531518en-000601 / 136R0283