Application Guide | iC7 Series Industry
Selection Number
Selection Name
0
Open loop
1
Closed loop with Feedback Device 1
2
Closed loop with Feedback Device 2
P 4.3.1.6 Motor Feedback Test Mode
Select the motor feedback test mode.
Default Value:
0 (Off)
Parameter
421
Number:
Data Type:
UINT
The following are the selections for the parameter.
Selection Number
Selection Name
0
Off
1
Enable Motor Feedback Test
P 4.3.1.9 Maximum Motor Voltage
Set the maximum output voltage applied to the motor. This can be used to avoid a field-weakening operation when running at speeds
above the nominal motor speed, when the drive is supplied with a voltage higher than the nominal motor voltage.
Default Value:
400
Parameter
5433
Number:
Data Type:
REAL
P 4.3.1.10 Motor Voltage Limitation Mode
Motor voltage limitation mode selection. The limitation is performed based on the DC-link voltage. 0=average DC-link voltage,
1=minimum DC-link voltage.
Default Value:
0 (Average DC-link voltage)
Parameter
4620
Number:
Data Type:
UINT
The following are the selections for the parameter.
© 2024.05
Selection Description
The motor is operated without feedback. The motor control
estimates the actual speed.
The motor is operated with feedback, providing speed and
position feedback for motor control from feedback device 1.
The motor is operated with feedback, providing speed and
position feedback for motor control from feedback device 2.
Parameter Type:
Unit:
Access Type:
Selection Description
Motor feedback test is not enabled.
The next start command initiates a test of the motor feedback
signal.
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
AB480436531518en-000601 / 136R0283 |
Parameter Descriptions
Selection
–
Read/Conditional Write
Range (0 — 1000)
V
Read/Write
Selection
–
Read/Write
123