Selection Number
Selection Name
3
Warning
10
Fault

Feedback Handling (Menu Index 5.2.16)

6.6.3.8
P 5.2.16.1 Failure Handling Response
Select the drive response to an encoder/resolver failure.
Default Value:
10 (Coast)
Parameter
4600
Number:
Data Type:
UINT
The following are the selections for the parameter.
Selection Number
Selection Name
3
Switch to Open Loop and Continue
9
Switch to Open Loop and Ramp to Stop
10
Coast
6.6.4

Load (Menu Index 5.3)

6.6.4.1

Load Status (Menu Index 5.3.1)

P 5.3.1.1 Inertia Estimation Status
Shows the status of the inertia estimation routine. 0 = Inactive, 1 = In progress, 2 = Completed successfully, 3 = Completed
unsuccessfully.
Default Value:
NA
Parameter
666
Number:
Data Type:
UINT
The following are the selections for the parameter.
Selection Number
Selection Name
0
Inactive
1
In progress
2
Completed successfully
3
Completed unsuccessfully
154
| © 2024.05
Selection Description
The drive issues a warning.
The drive issues a fault.
Parameter Type:
Unit:
Access Type:
Selection Description
The drive switches to open loop operation and continues
running.
The drive switches to open loop operation and ramps down to
stop.
The drive coasts the motor.
Parameter Type:
Unit:
Access Type:
Selection Description
Parameter Descriptions
Selection
Read/Write
Selection
Read Only
AB480436531518en-000601 / 136R0283