Application Guide | iC7 Series Industry
Figure 80: Preventive maintenance parameters in MyDrive Insight
1.
Define the maintenance Trigger Type.
Select how the need for maintenance is determined. There are four trigger types:
Disabled (default)
¢
Running Hours (the running hours of the motor)
¢
Operation Hours (the running hours of the drive)
¢
Number of Starts
¢
2.
Define the maintenance Interval. The interval is the number of hours or number of motor starts after which maintenance is
called for.
3.
Press Apply to finish setting the parameters.
When a need for maintenance is triggered, the drive issues a warning and shows the maintenance request in MyDrive Insight and on the
control panel.
To remove the maintenance request, the notification must be acknowledged by clicking OK in MyDrive Insight or pressing the OK button
on the control panel. Acknowledging removes the warning and schedules a new service trigger with the same values (for example 1000
running hours).