Application Guide | iC7 Series Industry
Selection Number
0
1
P 9.4.6.6 T17 Trigger Mode
Description: Select the trigger mode for the digital input.
Default Value: 0 [None]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
P 9.4.6.7 T17 Pulse Min. Frequency
Description: Set the frequency representing 0% of the signal.
Default Value:
Unit: Hz
P 9.4.6.8 T17 Pulse Max. Frequency
Description: Set the frequency representing 100% of the signal.
Default Value: 110000
Unit: Hz
Input T18 (Menu Index 9.4.7)
6.10.2.2.8
P 9.4.7.1 T18 Terminal Mode
Description: Select the mode for the terminal.
Default Value: 3 [Digital input]
Unit: -
© 2024.05
Selection Name
Standard reaction time (1ms tick)
Fast reaction time (0.5µs tick)
Parameter Type: Selection
Data Type: UINT
Selection Name
None
Rising Edge
Falling Edge
Both Edges
Parameter Type: Range (0 — 110000)
Data Type: REAL
Parameter Type: Range (0 — 110000)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Parameter Descriptions
Selection Description
Use the digital input in the same way as
other inputs.
Enables a fast reaction time for a certain
event via digital input.
Parameter Number: 2036
Access Type: Read/Write
Selection Description
No event trigger.
Trigger an event at the rising edge.
Trigger an event at the falling edge.
Trigger an event at both the rising and
falling edges.
Parameter Number: 2037
Access Type: Read/Write
Parameter Number: 2038
Access Type: Read/Write
Parameter Number: 2018
Access Type: Read/Write
AB480436531518en-000601 / 136R0283 |
329
Need help?
Do you have a question about the iC7 Series and is the answer not in the manual?