Application Guide | iC7 Series Industry
Data Type:
USINT
The following are the selections for the parameter.
Selection Number
Selection Name
0
Hz
1
RPM
Control Panel (Menu Index 8.3)
6.9.4
General Settings (Menu Index 8.3.1)
6.9.4.1
S 8.3.1.2 Time & Date Settings
General control panel date and time settings.
Set the system time zone, and select the date and time format to be shown on the control panel.
Status Line (Menu Index 8.3.2)
6.9.4.2
P 8.3.2.1 Status Line Left
Select the parameter for the left field in the status line.
Default Value:
1 (Actual Control Value)
Parameter
4332
Number:
Data Type:
UDINT
The following are the selections for the parameter.
Selection Number
Selection Name
0
None
1
Actual Control Value
2
Automatic Reference
9011
Motor Speed
9000
Motor Current
9010
Motor Shaft Speed
9009
Motor Torque
1708
Relative Motor Torque
9005
Motor Voltage
9008
Motor Shaft Power
674
Load Drooping Speed
666
Estimated Inertia
298
| © 2024.05
Access Type:
Selection Description
Use Hz as speed unit.
Use RPM as speed unit.
Parameter Type:
Unit:
Access Type:
Selection Description
Nothing selected.
Shows the reference depending on operation mode.
Shows the actual motor speed.
Shows the actual motor current.
Shows the shaft speed in RPM.
Shows the actual motor torque.
Shows the motor torque in % of the nominal motor torque.
Shows the actual motor voltage.
Shows the actual power at the motor shaft.
Shows the load drooping speed.
Parameter Descriptions
Read/Write
Selection
–
Read/Write
AB480436531518en-000601 / 136R0283