Application Guide | iC7 Series Industry
P 5.9.2.36 Regenerative Torque Limit Delay
Set the delay the drive is allowed to be in regenerative torque limit before a response is issued.
Default Value:
Parameter Type:
Parameter
2363
Number:
Data Type:
REAL
Torque Reference (Menu Index 5.9.3)
6.6.10.4
P 5.9.3.1 Torque Reference 1 Input
Select the input terminal or a predefined fixed value for the torque reference.
Default Value:
Parameter
4534
Number:
Data Type:
UINT
Selection lists with inputs and/or outputs consist of the name of the hardware option and the numbers of the
NOTE:
terminals. For example, terminal number 13 of the Basic I/O is called Basic I/O T13 in the selection list.
P 5.9.3.2 Torque Reference 2 Input
Select the input terminal or a predefined fixed value for the torque reference.
Default Value:
Parameter
4535
Number:
Data Type:
UINT
Selection lists with inputs and/or outputs consist of the name of the hardware option and the numbers of the
NOTE:
terminals. For example, terminal number 13 of the Basic I/O is called Basic I/O T13 in the selection list.
P 5.9.3.3 Torque Reference 1 Max.
Set the maximum torque reference value in % of nominal motor torque.
Default Value:
100
Parameter
4530
Number:
Data Type:
REAL
P 5.9.3.4 Torque Reference 1 Min.
Set the minimum torque reference value in % of nominal motor torque.
Default Value:
Parameter Type:
228
| © 2024.05
Range (0 — 65000)
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Parameter Type:
Unit:
Access Type:
Range (-300 — 300)
Parameter Descriptions
s
Read/Write
Selection
Read/Write
Selection
Read/Write
Range (-300 — 300)
%
Read/Write
AB480436531518en-000601 / 136R0283