BOOL
The following are the selections for the parameter.
Selection Number
Selection Name
0
Disabled
1
Enabled
This parameter enables the retry functionality (fault ride-through) after 1 of the common power conversion protections has activated.
The number of retries or the retrying window depends on the power unit type and rating. The protections that can utilize retry are:
Output current ground leakage fault
l
Output overcurrent faults
l
DC-link overvoltage and undervoltage faults
l
Brake resistor or switching element short circuit faults
l
P 2.3.1.2 Smart Derate Mode
Select the level of derating if the drive's nominal operational limits have been exceeded.
Default Value:
0 (Maximum derating)
Parameter
2345
Number:
Data Type:
UINT
The following are the selections for the parameter.
Selection Number
Selection Name
0
Maximum derating
1
Minimum derating
This parameter selects a level for the derating of the switching frequency whenever it is needed. The drive features multiple protection
functions that can derate the switching frequency of the drive, to avoid operating conditions that are harmful for the drive. This
parameter can be used to influence the degree of derating. Following are the descriptions of the selections for this parameter:
Table 27: Selection Descriptions
Selection Name
Maximum Derating Mode
Minimum Derating Mode
P 2.3.1.3 DC-link Voltage Ripple Response
Select the mode of excessive DC-link voltage ripple protection.
96
| © 2024.05
Selection Description
When switching frequency derating is applied, the drive reduces the switching frequency to the
maximum. This depends on the application scenario.
When switching frequency derating is applied, the drive reduces the switching frequency to the
minimum. This depends on the application scenario.
Access Type:
Selection Description
Disables the function.
Enables the function.
Parameter Type:
Unit:
Access Type:
Selection Description
Drive derates as much as possible.
Drive derates as little as possible.