M16C/64C Group
14.2.7

Address Match Interrupt Enable Register (AIER)

Address Match Interrupt Enable Register
b7 b6 b5 b4
b3
b2
b1
14.2.8

Address Match Interrupt Enable Register 2 (AIER2)

Address Match Interrupt Enable Register 2
b7 b6 b5 b4
b3
b2
b1
R01UH0092EJ0110 Rev.1.10
Jul 31, 2012
b0
Symbol
AIER
Bit Symbol
Bit Name
Address match interrupt 0
AIER0
enable bit
Address match interrupt 1
AIER1
enable bit
No register bits. If necessary, set to 0. The read value is undefined.
(b7-b2)
Symbol
b0
AIER2
Bit Symbol
Bit Name
Address match interrupt 2
AIER20
enable bit
Address match interrupt 3
AIER21
enable bit
No register bits. If necessary, set to 0. The read value is undefined.
(b7-b2)
Address
020Eh
Function
0 : Interrupt disabled
1 : Interrupt enabled
0 : Interrupt disabled
1 : Interrupt enabled
Address
020Fh
Function
0 : Interrupt disabled
1 : Interrupt enabled
0 : Interrupt disabled
1 : Interrupt enabled
14. Interrupts
Reset Value
XXXX XX00b
RW
RW
RW
Reset Value
XXXX XX00b
RW
RW
RW