Input Capture Mode (Operating Pmc0 And Pmc1 Independently) - Renesas M16C/64C User Manual

Table of Contents

Advertisement

M16C/64C Group
22.3.4

Input Capture Mode (Operating PMC0 and PMC1 Independently)

The input capture mode measures width or period of external pulse. PMC0 and PMC1 can be
measured independently.
Table 22.16
Input Capture Mode Specifications (Independent Operation)
Item
Clock sources
Count
sources
Division
Count operation
Measured items
Interrupt request generation
timing
Selectable functions
R01UH0092EJ0110 Rev.1.10
Jul 31, 2012
PMC0 Circuit
One of the following:
fC
f1
Timer B2 underflow
Count source of PMC1
No division, divided-by-8, divided-by-32, or divided-by-64
Increment
One of the following:
Pulse period (between rising edge and rising edge)
Pulse period (between falling edge and falling edge)
Pulse width (both high level and low level)
Timer measurement
Counter overflow
Input signal inversion
Digital filter
22. Remote Control Signal Receiver
Content
PMC1 Circuit
One of the following:
fC
f1
Timer B1 underflow
Timer B2 underflow