Renesas M16C/64C User Manual page 480

Table of Contents

Advertisement

M16C/64C Group
Refer to 14.7 "Interrupt Control" for details on interrupt control. Table 22.23 lists Registers Associated with
Remote Control Signal Receiver Interrupts.
Table 22.23
Registers Associated with Remote Control Signal Receiver Interrupts
Address
UART7 Bus Collision Detection Interrupt Control
0071h
Register, Remote Control Signal Receiver 0 Interrupt
Control Register
UART7 Transmit Interrupt Control Register, Remote
0072h
Control Signal Receiver 1 Interrupt Control Register
0206h
Interrupt Source Select Register 2
The remote control signal receiver shares interrupt vectors or interrupt control registers with other
peripheral functions. To use the remote control signal receiver 0 interrupt, set the IFSR24 bit in the
IFSR2A register to 1 (remote control signal receiver 0). To use the remote control signal receiver 1
interrupt, set the IFSR25 bit in the IFSR2A register to 1 (remote control signal receiver 1).
R01UH0092EJ0110 Rev.1.10
Jul 31, 2012
Register
22. Remote Control Signal Receiver
Symbol
Reset Value
U7BCNIC/
XXXX X000b
PMC0IC
S7TIC/PMC1IC
XXXX X000b
IFSR2A
00h
Page 447 of 807