Toshiba H1 Series Data Book page 66

32bit micro controller tlcs-900/h1 series
Table of Contents

Advertisement

Table 3.4.19 Information Returned for the Microcontroller Information Command
Microcontroller Information
TMP92CZ26A
Table 3.4.20 Information Returned for the User Program Transfer Result Command
Transfer Result
No error
User program not received
Received file not in Intel Hex format
User program size error
Download address error
Protocol error or other error
54H, 4DH, 50H, 39H, 32H, 43H, 5AH, 32H, 36H,20H, 20H, 20H, 20H, 20H, 20H
Value
00H
02H
The user program transfer result is received without the user program
transfer start command being received first.
04H
The first data of a user program is not ":" (3AH).
06H
The size of a received user program is larger than the value set in
wIndex of the user program transfer start command.
08H
The specified user program download address is not in the designated
area.
The user program size is over 10 Kbytes.
0AH
The user program transfer start or user program transfer result
command is received first.
A checksum error is detected in the Intel Hex file.
A record type error is detected in the Intel Hex file.
The length of an address record in the Intel Hex file is 3 or longer.
The length of an end record in the Intel Hex file is other than 0.
92CZ26A-63
ASCII Code
Error Conditions
TMP92CZ26A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tlcs-900Tmp92cz26axbg

Table of Contents