(18) AD converter (3/3)
Symbol
Name
Address
AD mode
ADMOD0
control
12B8H
register 0
AD mode
ADMOD1
control
12B9H
register 1
AD mode
ADMOD2
control
12BAH
register 2
AD mode
ADMOD3
control
12BBH
register 3
AD mode
ADMOD4
control
12BCH
register 4
AD mode
ADMOD5
control
12BDH
register 5
7
6
EOS
BUSY
R
0
0
Normal AD
Normal AD
conversion
conversion
end flag
BUSY Flag
0:During
conversion
0:Stop
sequence
conversion
or before
1:During
starting
conversion
1:Complete
conversion
sequence
DACON
ADCH2
ADCH1
0
0
DAC and VREF
Analog input channel select
application
control
HEOS
HBUSY
R
0
0
High-priority
High-priority AD
AD conversion
conversion
sequence
BUSY Flag
FLAG
0: During
0:Stop
conversion
conversion
sequence
1:During
or before
conversion
starting
1: Complete
conversion
sequence
HADCH2
HADCH1
R/W
0
0
High-priority analog input channel
Always
select
write "0".
CMEN1
CMEN0
CMP1C
0
0
AD Monitor
AD Monitor
Generation
function1
function0
condition of
AD monitor
0: Disable
0: Disable
function
1: Enable
1: Enable
interrupt 1
0: less than
1: Greater than
or Equal
CMCH2
CM1CH1
R/W
0
Select analog channel for AD monitor function 1
000: AIN0
100: AN4
001: AIN1
101: AN5
010: AIN2
110: Reserved
011: AN3
111: Reserved
92CZ26A-740
5
4
3
I2AD
ADS
0
0
AD conversion
Start Normal
when
AD conversion
IDLE2 mode
0: Don't Care
1:Start
0: Stop
AD conversion
1: Operate
Always read
as"0".
ADCH0
LAT
R/W
0
0
0
Latency
0: No Wait
1:Start after
reading
conversion
result store
Register of
last channel
HADS
0
Start
High-priority
AD conversion
0: Don't Care
1: Start AD
conversion
Always read
as"0".
HADCH0
0
0
CMP0C
IRQEN1
R/W
0
0
0
Generation
AD monitor
condition of
function
AD monitor
interrupt 1
function
0: Disable
interrupt 0
1: Enable
0: less than
(Note)
1: Greater than
or Equal
CM1CH0
0
0
TMP92CZ26A
2
1
0
HTRGE
TSEL1
TSEL0
R/W
0
0
Normal AD
Select Hard ware trigger
conversion at
Hard ware
00: INTTB00 interrupt
trigger
01: Reserved
0: Disable
10: ADTRG
1: Enable
11: Reserved
ITM
REPEAT
SCAN
0
0
Interrupt
Repeat mode
Scan mode
specification
specification
specification
when
0: Single
0: Channel
conversion
conversion
fixed mode
channel fixed
1: Repeat
1: Channel
repeat mode
conversion
scan mode
HHTRGE
HTSEL1
HTSEL0
R/W
0
0
High-priority
Select Hard ware trigger
AD conversion
00: INTTB10 interrupt
at Hard ware
01: Reserved
trigger
10: ADTRG
0: Disable
11: I2S Sampling Counter
1: Enable
Output
R/W
Always
write "0".
IRQEN0
CMPINT1 CMPINT0
0
0
AD monitor
Status of
AD
Status of
function
monitor
monitor
interrupt 0
function
function
interrupt 1
interrupt 0
0: Disable
0: No
0: No
1: Enable
generation
generation
(Note)
1: Generation
1: Generation
CM0CH2
CM0CH1
CM0CH0
R/W
0
0
Select analog channel for AD monitor function
1
000: AIN0
100: AN4
001: AIN1
101: AN5
010: AIN2
110: Reserved
011: AN3
111: Reserved
0
0
0
0
AD