Toshiba H1 Series Data Book page 48

32bit micro controller tlcs-900/h1 series
Table of Contents

Advertisement

3.4.3
Outline of Boot Operation
The method for downloading a user program can be selected from two types: from UART,
or via USB.
After reset, the boot program on the internal boot ROM executes as shown in Figure 3.4.2.
Regardless of the downloading method used, the boot program downloads a user program
into the internal RAM and then branches to the internal RAM. Figure 3.4.3 shows how the
boot program uses the internal RAM (common to all the downloading methods).
RESUME check
PMCCTL<PCM_ON>=1
Clock setting
f
f
No
Branch to internal RAM
Note 1: To download a user program via USB, a USB device driver and special application software are needed on
the PC.
Note 2: To download a user program via UART, special application software is needed on the PC.
Note 3: The (a), (b) in the above flowchart indicate points where the settings of external port pins are changed. For
details, see Table 3.4.3.
Figure 3.4.2 Flowchart for Internal Boot ROM Operation
Start
No
= f
SYS
OSCH
= f
× 24/5
USB
OSCH
(a)
UART
check
No
USB
check
Yes
Download via
USB
3000h
92CZ26A-45
Yes
(b)
Yes
Download via UART
TMP92CZ26A
Branch to internal RAM
46000h

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tlcs-900Tmp92cz26axbg

Table of Contents