SECTION 4

4.3.1.3 STATUS KEY

The STATUS key is used to display the operating status of the Power Source.
This key may be pressed at any time power is applied to the cabinet. Based on
internal sense circuits one of the following messages may be displayed.
S1
Displayed when the Power Source is in an Emergency Off state. The
EMER OFF lamp shall be lit.
S1: CAB EMER OFF- WARNING - NO OUTPUT
S2
Displayed when the Power Source is in the Normal Off state. The OFF
lamp shall be lit.
S2: CAB IS OFF – READY FOR OPERATION
S3
Displayed when the Power Source is in the Standby state. The STANDBY
lamp shall be lit.
S3: CAB IS STBY - READY FOR OPERATION
S4
Displayed when the Power Source is in the Normal ON state. The ON
lamp shall be lit. Output Frequency and %LOAD (the highest percent load
shown in the Output O2 message) is displayed. Single Cabinet output
volts and amps information are displayed for each phase.
S4: CAB IS ON - OPERATION NORMAL
FREQ=XXX.X %LOAD XXX
S5
Displayed when the Power Source is OVERLOADED. The Power Source
is overloaded when %LOAD is greater than 100%. The ON lamp shall be
lit. Output Frequency and %LOAD (the highest percent load as shown in
the Output O2 message) is displayed. Single Cabinet output volts and
amps information are displayed for each phase.
S5: CAB IS ON - WARNING - OVERLOAD
FREQ=XXX.X %LOAD XXX
Pacific Power Source ©2013
PRESS DIAG KEY
V
XXX/XXX XXX/XXX XXX/XXX
A
XXX
XXX
V
XXX/XXX XXX/XXX XXX/XXX
A
XXX
XXX
4-8
OPERATION
XXX
XXX
Document # 126050-10 Rev E