6. ROM
Bit 2—Program-Verify (PV)*
set the SWE, ESU, PSU, EV, E, or P bit at the same time.)
Bit 2: PV
Description
0
Program-verify mode cleared
1
Transition to program-verify mode
[Setting condition]
When FWE = 1 and SWE = 1
1
3
Bit 1—Erase (E)*
*
PSU, EV, PV, or P bit at the same time.)
Bit 1: E
Description
0
Erase mode cleared
1
Transition to erase mode
[Setting condition]
When FWE = 1, SWE = 1, and ESU = 1
Bit 0—Program (P)*
ESU, PSU, EV, PV, or E bit at the same time.)
Bit 0: P
Description
0
Program mode cleared
1
Transition to program mode
[Setting condition]
When FWE = 1, SWE = 1, and PSU = 1
Notes: 1. Do not set multiple bits simultaneously. Do not cut V
2. The SWE bit must not be set or cleared at the same time as other bits (bits EV, PV, E,
and P in FLMCR1, and bits ESU and PSU in FLMCR2).
3. P bit and E bit setting should be carried out in accordance with the program/erase
algorithms shown in section 6.5, Flash Memory Programming/Erasing. Before setting
either of these bits, a watchdog timer setting should be made to prevent program
runaway. See section 6.9, Flash Memory Programming and Erasing Precautions, for
more information on the use of these bits.
Rev.3.00 Jul. 19, 2007 page 128 of 532
REJ09B0397-0300
1
: Bit 2 selects program-verify mode transition or clearing. (Do not
: Bit 1 selects erase mode transition or clearing. (Do not set the SWE, ESU,
1
3
*
: Bit 0 selects program mode transition or clearing. (Do not set the SWE,
while a bit is set.
CC
(initial value)
(initial value)
(initial value)