Renesas FP-64E User Manual
Renesas FP-64E User Manual

Renesas FP-64E User Manual

System interface cable for e6000 emulator
Hide thumbs Also See for FP-64E:

Advertisement

Quick Links

To our customers,
Old Company Name in Catalogs and Other Documents
st
On April 1
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website:
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
http://www.renesas.com
st
April 1
, 2010
Renesas Electronics Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Renesas FP-64E

  • Page 1 On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
  • Page 2 Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
  • Page 3 H8/36014 Group, H8/36024 Group FP-64E User System Interface Cable for E6000 Emulator User’s Manual HS36014ECH61H Renesas Microcomputer Development Environment System Rev.2.0 2003.12...
  • Page 4 6. The prior written approval of Renesas Technology Corp. is necessary to reprint or reproduce in whole or in part these materials. 7. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination.
  • Page 5: Important Information

    Renesas) pursues a policy of continuing improvement in design, performance, functions, and safety of the user system interface cable. Renesas reserves the right to change, wholly or partially, the specifications, design, user's manual, and other documentation at any time without notice.
  • Page 6: Limited Warranty

    User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of Renesas's warranty.
  • Page 7 This user's manual and user system interface cable are copyrighted and all rights are reserved by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any form, in hard-copy or machine-readable form, by any means available without Renesas's prior written consent.
  • Page 8 • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol.
  • Page 9 Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance.
  • Page 10 The HS36014ECH61H is a user system interface cable that connects an H8/36014 series E6000 emulator (HS3664EPI61H; hereinafter referred to as the emulator) to the IC socket for an FP-64E package for the H8/36014 series MCU on the user system and to the H8/36024 series expansion...
  • Page 11: Table Of Contents

    Section 1 Configuration...1 Section 2 Connection Procedures ...3 Connecting User System Interface Cable to Emulator Station (H8/36014 Series)... 3 Connecting User System Interface Cable to Expansion I/O Board (H8/36024 Series)... 5 Connecting User System Interface Cable to User System... 7 2.3.1 Installing IC Socket...
  • Page 12: Section 1 Configuration

    Section 1 Configuration Use an IC149-064-075-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64E package IC socket on the user system. Figure 1 shows the configuration of the HS36014ECH61H user system interface cable for the FP-64E package. Figure 1 HS36014ECH61H User System Interface Cable...
  • Page 13 Quantity Remarks Cable For the FP-64E package For installing an FP-64E-packaged MCU For fastening cable head (with four flat washers) For installing an FP-64E-packaged MCU (with four flat washers) For fastening the emulator station User’s manual for HS36014ECH61H (this manual)
  • Page 14: Section 2 Connection Procedures

    Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station (H8/36014 Series) Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
  • Page 15 Figure 2 Connecting User System Interface Cable to Emulator Station...
  • Page 16: Connecting User System Interface Cable To Expansion I/O Board (H8/36024 Series)

    Connecting User System Interface Cable to Expansion I/O Board (H8/36024 Series) Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
  • Page 17 Expansion I/O board cable Cable body connector CTS screws (M3 x 6 mm) User system interface cable Figure 3 Connecting User System Interface Cable to Expansion I/O Board...
  • Page 18: Connecting User System Interface Cable To User System

    2.3.2 Soldering IC Socket After fastening, solder the IC socket for an FP-64E package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly more solder than the MCU.)
  • Page 19: Inserting Cable Head

    Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-64E package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4.
  • Page 20 Fasten the user system interface cable head to the IC socket for an FP-64E package on the user system with the four screws (M2 12 mm; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
  • Page 21: Fastening Cable Body

    2.3.5 Fastening Cable Body Connect the cable body to the cable head. Figure 5 Fastening Cable Body...
  • Page 22: Recommended Dimensions For User System Mount Pad

    Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-64E package (IC149-064-075-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad.
  • Page 23: Dimensions For User System Interface Cable Head

    Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7 Dimensions for User System Interface Cable Head...
  • Page 24: Resulting Dimensions After Connecting User System Interface Cable

    Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Figure 8 Resulting Dimensions after Connecting User System Interface Cable...
  • Page 25: Section 3 Installing The Mcu To The User System

    Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.29 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 26 Figure 9 Installing MCU to User System...
  • Page 27: Section 4 Verifying Operation

    Section 4 Verifying Operation 1. When using the H8/36014 series E6000 emulator (HS3664EPI61H), turn on the emulator according to the procedures described in the H8/300H Series E6000 Emulator User's Manual (HS300HEPI61HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins.
  • Page 28 Figure 10 shows the system clock oscillator on the user system interface cable. Figure 10 System Clock Oscillator...
  • Page 29: Section 5 Notice

    1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.
  • Page 30 6. The P1 short connector is used for testing. Do not remove the inserted jumper pin. Figure 12 P1 Short Connector...
  • Page 31 Publication Date: Rev.1.00, March 18, 2002 Rev.2.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2002, 2003 Renesas Technology Corp. All rights reserved. Printed in Japan...
  • Page 32 H8/36014 Group, H8/36024 Group FP-64E User System Interface Cable for E6000 Emulator User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10B0091-0200H...

Table of Contents