Hitachi H8/3048 Hardware Manual page 373

Single-chip microcomputer
Table of Contents

Advertisement

www.DataSheet4U.com
TCNT4
OVF
Buffer transfer
signal (BR to GR)
GR
In channel 3, IMFA is set to 1 only during up-counting. In channel 4, OVF is set to 1 only when an
underflow occurs. When buffering is selected, buffer register contents are transferred to the
general register at compare match A3 during up-counting, and when TCNT4 underflows.
General Register Settings in Complementary PWM Mode: When setting up general registers
for complementary PWM mode or changing their settings during operation, note the following
points.
Initial settings
Do not set values from H'0000 to T – 1 (where T is the initial value of TCNT3). After the
counters start and the first compare match A3 event has occurred, however, settings in this
range also become possible.
Changing settings
Use the buffer registers. Correct waveform output may not be obtained if a general register is
written to directly.
Cautions on changes of general register settings
Figure 10-39 shows six correct examples and one incorrect example.
Underflow
H'0001
H'0000
Set to 1
Buffer transfer
Figure 10-38 Undershoot Timing
361
Overflow
H'FFFF
H'0000
Flag not set
No buffer transfer

Advertisement