Show System Environment - Allied Telesis AR2050V Command Reference Manual

Secure, for alliedware plus version 5.4.7-1.x
Table of Contents

Advertisement

S
C
M
YSTEM
ONFIGURATION AND

SHOW SYSTEM ENVIRONMENT

show system environment
Overview
This command displays the current environmental status of your device and any
attached PSU, XEM, or other expansion option. The environmental status covers
information about temperatures, fans, and voltage.
For information on filtering and saving command output, see the
with AlliedWare Plus" Feature Overview and Configuration
show system environment
Syntax
Mode
User Exec and Privileged Exec
Example
To display the system's environmental status, use the command:
awplus#
Output
Figure 6-16: Example output from show system environment
awplus#show system environment
Environment Monitoring Status
Overall Status: ***Fault***
Resource ID: 1
Name: AR4050S
ID
Sensor (Units)
1
Fan: Fan (Rpm)
2
Voltage: 2.5V (Volts)
3
Voltage: Battery (Volts)
4
Voltage: 3.3V (Volts)
5
Voltage: 5.0V (Volts)
6
Voltage: 12V (Volts)
7
Voltage: 0.92V (Volts)
8
Temp: Internal (Degrees C)
Related
show system
Commands
C613-50186-01 Rev B
C
ONITORING
OMMANDS
show system environment
Command Reference for AR2050V
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
Reading
Low Limit High Limit Status
3516
2411
2.461
2.344
1.181
2.700
3.266
2.973
4.974
4.505
11.563
10.813
0.844
0.872
32
58(Hyst)
"Getting Started
Guide.
-
Ok
2.865
Ok
3.586
FAULT
3.627
Ok
5.495
Ok
13.188
Ok
0.970
FAULT
65
Ok
256

Hide quick links: