Shutdown - Allied Telesis AR2050V Command Reference Manual

Secure, for alliedware plus version 5.4.7-1.x
Table of Contents

Advertisement

I
C
NTERFACE
OMMANDS

SHUTDOWN

shutdown
Overview
This command shuts down the selected interface. This administratively disables
the link and takes the link down at the physical (electrical) layer.
Use the no variant of this command to disable this function and therefore to bring
the link back up again.
Syntax
shutdown
no shutdown
Mode
Interface Configuration
Usage
If you shutdown an aggregator, the device shows the admin status of the
aggregator and its component ports as "admin down". While the aggregator is
down, the device accepts shutdown and no shutdown commands on
component ports, but these have no effect on port status. Ports will not come up
again while the aggregator is down.
Example
To shut down port1.0.2, use the commands:
awplus#
awplus(config)#
awplus(config-if)#
To bring up port1.0.2, use the commands:
awplus#
awplus(config)#
awplus(config-if)#
To shut down vlan2, use the commands:
awplus#
awplus(config)#
awplus(config-if)#
To bring up vlan2, use the commands:
awplus#
awplus(config)#
awplus(config-if)#
C613-50186-01 Rev B
configure terminal
interface port1.0.2
shutdown
configure terminal
interface port1.0.2
no shutdown
configure terminal
interface vlan2
shutdown
configure terminal
interface vlan2
no shutdown