4.3 FT82 SERVOPACK with MECHATROLINK-III Communications References

4.3.1 List of Servo Parameters

Parameter
No.
Pn002
4-68
Name
Application Function
2
Selections 2
MECHATROLINK Command Position and Speed Control
Option
0
Reserved setting (Do not use.)

n.
X
1
Use TLIM as the torque limit.
2
Reserved setting (Do not use.)
3
Reserved setting (Do not use.)
Torque Control Option

n.
X
0
Reserved setting (Do not use.)
Use the speed limit for torque control (VLIM) as the
1
speed limit.
Encoder Usage
Use the encoder according to encoder specifica-
0
tions.

n.
X
1
Use the encoder as an incremental encoder.
Use the encoder as a single-turn absolute
2
encoder.
External Encoder Usage
0
Do not use an external encoder.
The external encoder moves in the forward direc-
1
tion for CCW motor rotation.

n.X
2
Reserved setting (Do not use.)
The external encoder moves in the reverse direc-
3
tion for CCW motor rotation.
4
Reserved setting (Do not use.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
0011h
4213h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
Setup
restart
Applicable
Reference
Motors
All
Applicable
Reference
Motors
All
Applicable
Reference
Motors
All
Rotary
Applicable
Reference
Motors
Rotary
Continued on next page.
Refer-
ence
*2
*2
*1
*1