4.3
FT82 SERVOPACK with MECHATROLINK-III Communications References
The following table lists the parameters.
Note: Do not change the following parameters from their default settings.
• Reserved parameters
• Parameters not given in this manual
• Parameters that are not valid for the Servomotor that you are using, as given in the parameter table
4.3.1
List of Servo Parameters
Parameter
No.
2
Pn000
2
Pn001
4.3 FT82 SERVOPACK with MECHATROLINK-III Communications References
Setting
Name
Range
Basic Function Selec-
0000h to
tions 0
10B1h
Rotation Direction Selection
n.
X
0
Use CCW as the forward direction.
1
Use CW as the forward direction. (Reverse Rotation Mode)
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Application Function
0000h to
Selections 1
1142h
Motor Stopping Method for Servo OFF and Group 1 Alarms
0
Stop the motor by applying the dynamic brake.
n.
X
Stop the motor by the applying dynamic brake and then release
1
the dynamic brake.
2
Coast the motor to a stop without the dynamic brake.
Overtravel Stopping Method
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as
1
the maximum torque and then servo-lock the motor.
n.
X
Decelerate the motor to a stop using the torque set in Pn406 as
2
the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A and then servo-lock the motor.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A and then let the motor coast.
Main Circuit Power Supply AC/DC Input Selection
Input AC power as the main circuit power supply using the L1, L2,
0
and L3 terminals (do not use shared converter).
n.
X
Input DC power as the main circuit power supply using the B1/
1
and
2 terminals or the B1 and
converter or the shared converter).
n.X
Reserved parameter (Do not change.)
4.3.1 List of Servo Parameters
Setting
Default
Applicable
Unit
Setting
Motors
–
0000h
All
–
0000h
All
2 terminals (use an external
When
Classi-
Refer-
Enabled
fication
ence
After
Setup
–
restart
Reference
*1
After
Setup
–
restart
Reference
*1
Reference
*1
Reference
*1
Continued on next page.
4-67
4