Safety Parameters
Item
Safety Integrity Level
Mission Time
Probability of Dangerous Failure per
Hour
Performance Level
Mean Time to Dangerous Failure of
Each Channel
Average Diagnostic Coverage
Stop Category
Safety Function
Hardware Fault Tolerance
Subsystem
Standards
IEC 61508
SIL3
IEC 62061
SILCL3
IEC 61508
10 years
PFH = 4.04 × 10
IEC 61508
IEC 62061
(4.04% of SIL3)
EN ISO 13849-1
PLe (Category 3)
EN ISO 13849-1
MTTFd: High
EN ISO 13849-1
DCavg: Medium
IEC 60204-1
Stop category 0
IEC 61800-5-2
STO
IEC 61508
HFT = 1
IEC 61508
B
Performance Level
20 years
PFH = 4.05 × 10
-9
[1/h]
(4.05% of SIL3)
-9
[1/h]
xxxi