4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
Parameter
No.
Pn006
4-142
Name
Application Function
2
Selections 6
Analog Monitor 1 Signal Selection
00
Motor speed (1 V/1,000 min
01
Speed reference (1 V/1,000 min
02
Torque reference (1 V/100% rated torque)
03
Position deviation (0.05 V/reference unit)
04
Position amplifier deviation (after electronic gear) (0.05 V/encoder pulse unit)
05
Position reference speed (1 V/1,000 min
06
Reserved setting (Do not use.)
07
Load-motor position deviation (0.01 V/reference unit)
Positioning completion (positioning completed: 5 V, positioning not com-
08

n.
XX
pleted: 0 V)
09
Speed feedforward (1 V/1,000 min
0A
Torque feedforward (1 V/100% rated torque)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V)
Completion of position reference distribution (completed: 5 V, not com-
0C
pleted: 0 V)
0D
External encoder speed (1 V/1,000 min
0E
Reserved setting (Do not use.)
0F
Reserved setting (Do not use.)
10
Main circuit DC voltage
11 to 5F
Reserved settings (Do not use.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
0002h
105Fh
-1
)
-1
)
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
Immedi-
All
Setup
ately
-1
)
-1
)
-1
: value at the motor shaft)
Continued on next page.
Refer-
ence
*1