4.4 Command Option Attachable-type FT82 SERVOPACKs with INDEXER Modules
Parameter
No.
PnB05
PnB06
PnB07
PnB08
4-132
Name
2
/PGMRES; /JOGP
• When /MODE signal is ON (closed) (mode 0): Turn ON (close) the /PGMRES signal to
reset and cancel program table operation.
0000h
• When /MODE signal is OFF (open) (mode 1): Jog forward while the /JOGP signal is ON
(closed).
• When /MODE signal is ON (closed) (mode 0): Turn OFF (open) the /PGMRES signal to
reset and cancel program table operation.
0001h
• When /MODE signal is OFF (open) (mode 1): Jog forward while the /JOGP signal is OFF
(open).
• When /MODE signal is ON (closed) (mode 0): Do not reset program table operation.
0002h,
• When /MODE signal is OFF (open) (mode 1): Do not perform jogging.
0003h
2
/SEL0; /JOGN
• When /MODE signal is ON (closed) (mode 0): /SEL0 signal is active when ON (closed).
• When /MODE signal is OFF (open) (mode 1): Jog in reverse while the /JOGP signal is ON
0000h
(closed).
• When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is active when OFF (open).
• When /MODE signal is OFF (open) (mode 1): Jog in reverse while the /JOGN signal is OFF
0001h
(open).
• When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is always active.
0002h
• When /MODE signal is OFF (open) (mode 1): Do not perform jogging.
• When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is always inactive.
0003h
• When /MODE signal is OFF (open) (mode 1): Do not perform jogging.
2
/SEL1; /JOG0
• When /MODE signal is ON (closed) (mode 0): /SEL1 signal is active when ON (closed).
0000h
• When /MODE signal is OFF (open) (mode 1): /JOG0 signal is active when ON (closed).
• When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is active when OFF (open).
0001h
• When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is active when OFF (open).
• When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is always active.
0002h
• When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is always active.
• When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is always inactive.
0003h
• When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is always inactive.
2
/SEL2; /JOG1
• When /MODE signal is ON (closed) (mode 0): /SEL2 signal is active when ON (closed).
0000h
• When /MODE signal is OFF (open) (mode 1): /JOG1 signal is active when ON (closed).
• When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is active when OFF (open).
0001h
• When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is active when OFF (open).
• When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is always active.
0002h
• When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is always active.
• When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is always inactive.
0003h
• When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is always inactive.
Setting
Setting
Default
Range
Unit
Setting
0000h to
0000h
0003h
0000h to
0000h
0003h
0000h to
0000h
0003h
0000h to
0000h
0003h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
After
All
Setup
restart
After
All
Setup
restart
After
All
Setup
restart
Continued on next page.
Refer-
ence
*1
*1
*1
*1