YASKAWA SGM7D-30F Product Manual page 87

E-7-series ac servo drive e-7s servopack with ft/ex specification for application with special motor, sgm7d motor
Table of Contents

Advertisement

3.1 FT82 SERVOPACKs with Analog Voltage/Pulse Train References
3.1.3 Troubleshooting Alarms
Alarm Number:
Alarm Name
A.521:
Autotuning Alarm
(Vibration was
detected while
executing the
custom tuning,
Easy FFT, or the
tuning-less func-
tion.)
A.550:
Maximum Speed
Setting Error
A.710:
Instantaneous
Overload
A.720:
Continuous
Overload
A.730 and
A.731:
Dynamic Brake
Overload
(An excessive
power consump-
tion by the
dynamic brake
was detected.)
A.740:
Inrush Current
Limiting Resistor
Overload
(The main circuit
power supply
was frequently
turned ON and
OFF.)
3-18
Possible Cause
The Servomotor
vibrated considerably
Check the waveform of
while performing the
the motor speed.
tuning-less function.
The Servomotor
vibrated considerably
Check the waveform of
while performing cus-
the motor speed.
tom tuning or Easy
FFT.
Check the setting of
The setting of Pn385
Pn385, and the upper
(Maximum Motor
limits of the maximum
Speed) is greater than
motor speed setting
the maximum speed.
and the encoder output
resolution setting.
The wiring is not cor-
rect or there is a faulty
Check the wiring.
contact in the motor
or encoder wiring.
Operation was per-
Check the motor over-
formed that exceeded
load characteristics and
the overload protec-
Run command.
tion characteristics.
An excessive load
was applied during
Check the operation
operation because the
reference and motor
Servomotor was not
speed.
driven due to
mechanical problems.
A failure occurred in
the SERVOPACK.
The Servomotor was
Check the operation
rotated by an external
status.
force.
When the Servomo-
tor was stopped with
Check the power con-
the dynamic brake,
sumed by the DB resis-
the rotational or linear
tor to see how
kinetic energy
frequently the DB is
exceeded the capac-
being used.
ity of the dynamic
brake resistor.
A failure occurred in
the SERVOPACK.
The allowable fre-
quency of the inrush
current limiting resis-
tor was exceeded
when the main circuit
power supply was
turned ON and OFF.
A failure occurred in
the SERVOPACK.
Confirmation
Reduce the load so that
the moment of inertia ratio
is within the allowable
value. Or increase the
load level or reduce the
rigidity level in the tuning-
less level settings.
Check the operating pro-
cedure of corresponding
function and implement
corrections.
Set Pn385 to a value that
does not exceed the max-
imum motor speed.
Make sure that the Servo-
motor and encoder are
correctly wired.
Reconsider the load and
operating conditions. Or,
increase the motor
capacity.
Correct the mechanical
problem.
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
Implement measures to
ensure that the motor will
not be rotated by an
external force.
Reconsider the following:
• Reduce the Servomotor
command speed.
• Decrease the moment
of inertia ratio or mass
ratio.
• Reduce the frequency of
stopping with the
dynamic brake.
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
Reduce the frequency of
turning the main circuit
power supply ON and
OFF.
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
Continued from previous page.
Correction
Reference
*1
*1
*1
*1
Continued on next page.