Advertisement

Alarm
Alarm Name
Number
Maximum Speed Setting
A.550
Error
A.710
Instantaneous Overload
A.720
Continuous Overload
A.730
Dynamic Brake Overload
A.731
Inrush Current Limiting
A.740
Resistor Overload
Internal Temperature Error
A.7A1
1 (Control Board Tempera-
ture Error)
Internal Temperature Error
A.7A2
2 (Power Board Tempera-
ture Error)
Internal Temperature Sen-
A.7A3
sor Error
SERVOPACK Built-in Fan
A.7Ab
Stopped
A.810
Encoder Backup Alarm
A.820
Encoder Checksum Alarm
A.830
Encoder Battery Alarm
A.840
Encoder Data Alarm
A.850
Encoder Overspeed
A.860
Encoder Overheated
A.861
Motor Overheated
3.1 FT82 SERVOPACKs with Analog Voltage/Pulse Train References
Alarm Meaning
The setting of Pn385 (Maxi-
mum Motor Speed) is greater
than the maximum motor
speed.
The Servomotor was operat-
ing for several seconds to
several tens of seconds
under a torque that largely
exceeded the rating.
The Servomotor was operat-
ing continuously under a
torque that exceeded the rat-
ing.
When the dynamic brake was
applied, the rotational or lin-
ear kinetic energy exceeded
the capacity of the dynamic
brake resistor.
The main circuit power sup-
ply was frequently turned ON
and OFF.
The surrounding tempera-
ture of the control PCB is
abnormal.
The surrounding tempera-
ture of the power PCB is
abnormal.
An error occurred in the tem-
perature sensor circuit.
The fan inside the SERVO-
PACK stopped.
The power supplies to the
encoder all failed and the
position data was lost.
There is an error in the
checksum results for
encoder memory.
The battery voltage was
lower than the specified level
after the control power sup-
ply was turned ON.
There is an internal data error
in the encoder.
The encoder was operating
at high speed when the
power was turned ON.
The internal temperature of
the rotary encoder or linear
encoder is too high.
The internal temperature of
motor is too high.
3.1.2 List of Alarms
Continued from previous page.
Servo-
Alarm Code
Alarm
motor
Output
Reset
Stop-
Possi-
ping
ALO1 ALO2 ALO3
ble?
Method
Gr.1
Yes
L
H
Gr.2
Yes
L
L
Gr.1
Yes
L
L
Gr.1
Yes
L
L
Gr.1
Yes
L
L
Gr.2
Yes
L
L
Gr.2
Yes
L
L
Gr.2
No
L
L
Gr.1
Yes
L
L
Gr.1
No
H
H
Gr.1
No
H
H
Gr.1
Yes
H
H
Gr.1
No
H
H
Gr.1
No
H
H
Gr.1
No
H
H
Gr.1
No
H
H
Continued on next page.
L
L
L
L
L
L
L
L
L
H
H
H
H
H
H
H