Parameter
Name
No.
Output Signal Selec-
2
tions 10
/POUT0 (Programmable Output 0) Signal Allocation
n.
X
Pn635
/POUT1 (Programmable Output 1) Signal Allocation
n.
X
/POUT2 (Programmable Output 2) Signal Allocation
n.
X
/POUT3 (Programmable Output 3) Signal Allocation
n.X
Output Signal Selec-
2
tions 11
/POUT4 (Programmable Output 4) Signal Allocation
n.
X
Pn636
/POSRDY (Origin Return Completed Output) Signal Allocation
n.
X
/DEN (Positioning Reference Distribution Output) Signal Allocation
n.
X
n.X
Reserved parameter (Do not change.)
4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
Setting
Setting
Range
Unit
0000h to
–
6666h
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
The settings are the same as for /POUT0 (Programmable Output
0 to 6
0) Signal Allocation.
The settings are the same as for /POUT0 (Programmable Output
0 to 6
0) Signal Allocation.
The settings are the same as for /POUT0 (Programmable Output
0 to 6
0) Signal Allocation.
0000h to
–
0666h
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
The settings are the same as for /POUT4 (Programmable Output
0 to 6
4) Signal Allocation.
The settings are the same as for /POUT4 (Programmable Output
0 to 6
4) Signal Allocation.
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
0654h
All
restart
After
0000h
All
restart
Continued on next page.
Classi-
Refer-
fication
ence
−
Setup
Reference
*1
Reference
*1
Reference
*1
Reference
*1
−
Setup
Reference
*1
Reference
*1
Reference
*1
4
4-171