4.2 FT82 SERVOPACK with MECHATROLINK-II Communications References
Parameter
No.
Pn50E
Pn50F
Pn510
4-50
Name
Output Signal Selec-
2
tions 1
/COIN (Positioning Completion Output) Signal Allocation
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output terminal.

n.
X
2
Output the signal from the CN1-23 or CN1-24 output terminal.
3
Output the signal from the CN1-25 or CN1-26 output terminal.
4 to 6
Reserved setting (Do not use.)
/V-CMP (Speed Coincidence Detection Output) Signal Allocation

n.
X
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
/TGON (Rotation Detection Output) Signal Allocation

n.
X
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
/S-RDY (Servo Ready) Signal Allocation

n.X
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
Output Signal Selec-
2
tions 2
/CLT (Torque Limit Detection Output) Signal Allocation
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output terminal.

n.
X
2
Output the signal from the CN1-23 or CN1-24 output terminal.
3
Output the signal from the CN1-25 or CN1-26 output terminal.
4 to 6
Reserved setting (Do not use.)
/VLT (Speed Limit Detection) Signal Allocation

n.
X
The allocations are the same as the /CLT (Torque Limit Detection
0 to 6
Output) signal allocations.
/BK (Brake Output) Signal Allocation

n.
X
The allocations are the same as the /CLT (Torque Limit Detection
0 to 6
Output) signal allocations.
/WARN (Warning Output) Signal Allocation

n.X
The allocations are the same as the /CLT (Torque Limit Detection
0 to 6
Output) signal allocations.
Output Signal Selec-
2
tions 3
/NEAR (Near Output) Signal Allocation
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output terminal.

n.
X
2
Output the signal from the CN1-23 or CN1-24 output terminal.
3
Output the signal from the CN1-25 or CN1-26 output terminal.
4 to 6
Reserved setting (Do not use.)

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
0000h
6666h
0000h to
0100h
6666h
0000h to
0000h
0666h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
Reference
Reference
Reference
After
All
Setup
restart
Reference
Reference
Reference
Reference
After
All
Setup
restart
Reference
Continued on next page.
Refer-
ence
*1
*1
*1
*1
*1
*1
*1
*1
*1