3.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
3.5.8 INDEXER Warning Displays and Troubleshooting
Error No.
E5EE
E5FE
E63E
3-248
Alarm
Error Name
Number
Execution Dis-
abled during Pro-
A.9F9
gram Table
Operation Error
Session Conflict
A.9F9
Error
Continuous Stop
A.9F9
Execution Dis-
abled Error
Meaning
• There was a request to execute a process
that is not allowed during program table
operation while program table operation
was in progress or on hold.
• There was an attempt to change the pro-
gram table while program table operation
was in progress or on hold.
There was a request that could not be exe-
cuted at the same time as the function that
was being executed.
Example:
There was a request to start program table
operation while the program table was being
initialized.
An attempt was made to execute a continu-
ous stop under conditions where it could not
be executed.
Examples:
• The coordinates have been set to linear
moving method.
• The immediately-preceding table target
position is not ±INFINITE.
• The immediately-preceding table target
position is ±INFINITE, but the registration
distance is set.
• A value other than 1 has been set for the
execution count.
Continued from previous page.
Corrective Action
Request execution
of the process
again after cancel-
ing program table
operation by turn-
ing the
/PGMRES signal
ON.
Execute the oper-
ation again after
the execution of
the current func-
tion is completed.
Execute a continu-
ous stop under
conditions where
it can be exe-
cuted.